ðMain Office
    1013 Conshohocken Road
    Conshohocken, PA 19428

    610.825.8690
    info@hilberts.com

ðProducts
    Access Doors
    Acoustical Panels
    Air Curtains
    Air Rotation
    Bio-Medical Air Handlers
    Boiler Stack & Breeching
    Chilled Beams
    Curbs & Rails
    Dampers/Fire/Smoke/
       Combination

    DOAS
    Duct Take-Off Fittings
    Fabric Duct
    Fans
    FRP Duct
    Fume Extraction
    Grilles/Registers/Diffusers
    Hazardous Gas Sensing
  
Heat & Smoke Vents
    HEPA Filters
    Induction Diffusers
    Kitchen Hoods
    Lab, Fumehood & Room
       Controls

    Louvers
    Make Up Air Units
    Ridge Ventilators
    Sound Attenuators
    Spiral Duct
    Unit Ventilators
   
VAV Diffusers
   
VAV Terminals
    Vehicle Exhaust

LEED

Dadanco Active Chilled Beams

What is an active chilled beam?

With active chilled beam systems the building's primary/ventilation air is continuously supplied to the active chilled beam terminal units by the central air handling system. This primary/ventilation air is cooled or heated to partially handle the temperature-driven sensible loads, while in the summer being cooled/dehumidified enough to handle all of the internal moisture-driven latent loads.

Primary/ventilation air (1) is introduced into the active chilled beam through a series of nozzles (2). This induces room air (3) up into the active chilled beam and in turn through a secondary water coil (4). Induced room air is cooled and/or heated by the water coil to the extent needed to control the room temperature. Induced room air is then mixed with the primary/ventilation air and the mixed air (5) is discharged into the room.


 


Applied Air Commercial DOAS

The FAP is a new packed DOAS (Dedicated Outdoor Air System) from Applied Air. This unit is the product of over 6 years of research and design and was designed from the ground up to fully comply with the ventilation standards set forth in ASHRAE 62.1. Compliance with this standard is a prerequisite for LEED certification. The FAP is a modular unit that contains many features that historically were only available in custom units. These features include:

Our exclusive DHTD™ (Digital High Turn Down) burner (Patent Pending) with turn-down ratios up to 100 to 1. The most energy efficient indirect fired burner available.
Powerful plenum fan section that can produce up to 6"wg of static pressure. Long duct runs are no problem for the FAP.
MERV 7 filters standard with MERV 15 filters available for providing fresh clean ventilation air to your building.
Up to 6 rows of DX coil. These coils are essential to insure that the air you bring in to your building is cool and dry.
Patented ApdaptAire™ DDC controls that are BACnet, LON, N2, and modbus compatible
Up to 60 tons of DX cooling capacity utilizing the environmentally friendly 410A refrigerant.
Available re-heat coil option enables neutral air while complying with ASHRAE 90.1.


 


Moffitt Wind Driven Turbine Ventilator

The Hurricane™ Wind-Driven Turbine Gravity Ventilator allows users to ventilate their commercial or industrial building without the need for a powered roof exhaust fan. The unit requires no electrical or maintenance costs to operate, providing a 2-3 year payback on investment. It also offers a lower first cost because wiring, starter, and associated electrical costs are eliminated. With its lightweight aluminum design, no framing is required.

Aluminum construction available. 12", 24" and 36" throat sizes with various accessory options.


   

We are active members of the Sheet Metal Contractors Association of Philadelphia (SMCA) and the
American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)

Air Handling Equipment ▪ Grilles ▪ Registers ▪ Diffusers ▪ Fans ▪ Heating ▪ Cooling

Web Design by Tom Richards