What is an active chilled beam?
With active chilled beam systems the building's
primary/ventilation air is continuously supplied to
the active chilled beam terminal units by the
central air handling system. This
primary/ventilation air is cooled or heated to
partially handle the temperature-driven sensible
loads, while in the summer being cooled/dehumidified
enough to handle all of the internal moisture-driven
latent loads.
Primary/ventilation air (1) is introduced into the
active chilled beam through a series of nozzles (2).
This induces room air (3) up into the active chilled
beam and in turn through a secondary water coil (4).
Induced room air is cooled and/or heated by the
water coil to the extent needed to control the room
temperature. Induced room air is then mixed with the
primary/ventilation air and the mixed air (5) is
discharged into the room.

Applied Air
Commercial DOAS
The FAP is a new packed DOAS (Dedicated Outdoor
Air System) from Applied Air. This unit is the
product of over 6 years of research and design and
was designed from the ground up to fully comply with
the ventilation standards set forth in ASHRAE 62.1.
Compliance with this standard is a prerequisite for
LEED certification. The FAP is a modular unit that
contains many features that historically were only
available in custom units. These features include:
▪ Our exclusive DHTD™
(Digital High Turn Down) burner (Patent Pending)
with turn-down ratios up to 100 to 1. The most
energy efficient indirect fired burner available.
▪ Powerful plenum fan
section that can produce up to 6"wg of static
pressure. Long duct runs are no problem for the FAP.
▪ MERV 7 filters
standard with MERV 15 filters available for
providing fresh clean ventilation air to your
building.
▪ Up to 6 rows of DX
coil. These coils are essential to insure that the
air you bring in to your building is cool and dry.
▪ Patented ApdaptAire™
DDC controls that are BACnet, LON, N2, and modbus
compatible
▪ Up to 60 tons of DX
cooling capacity utilizing the environmentally
friendly 410A refrigerant.
▪ Available re-heat coil
option enables neutral air while complying with
ASHRAE 90.1.

Moffitt
Wind Driven Turbine Ventilator
The Hurricane™ Wind-Driven Turbine Gravity
Ventilator allows users to ventilate their
commercial or industrial building without the need
for a powered roof exhaust fan. The unit requires no
electrical or maintenance costs to operate,
providing a 2-3 year payback on investment. It also
offers a lower first cost because wiring, starter,
and associated electrical costs are eliminated. With
its lightweight aluminum design, no framing is
required.
Aluminum construction available. 12", 24" and 36"
throat sizes with various accessory options.
|
 |
|
We are
active members of the Sheet Metal Contractors
Association of Philadelphia (SMCA)
and the
American Society of Heating, Refrigerating
and Air-Conditioning Engineers (ASHRAE) |
|